| Targited Intraoperative Radiation Therapy (TARGIT) with INTRABEAM® |
| |
 INTRABEAM Miniature X-ray source | | INTRABEAM Miniature X-ray source
The radiation dose is provided by a miniature X-ray source PRS 500 that can deliver X-ray energies up to 50kV. The source has demonstrated stable output over years that is monitored and recorded on-line by mean of an internal radiation monitor. Low energy, high dose rate X-rays are emitted from the source in an isotropic pattern, uniformly irradiating the target tissue. |
| |
 INTRABEAM Control Console | | INTRABEAM Control Console
The control console ensures exact setting and monitoring of the desired dose. The critical treatment parameters are constantly monitored during the entire treatment for safe and accurate dose delivery. |
| |
 INTRABEAM Treatment Software | | INTRABEAM Treatment Software
The convenient step by step user guidance ensure a safe and quick way in performing the treatment. In clearly arranged folders all quality assurance steps, dose planning and prescription as well as the treatment itself and documentation can be done. The INTRABEAM planning software is safe and easy to use. |
| |
 INTRABEAM Spherical Applicator | | INTRABEAM Spherical Applicator
A complete set of spherical applicators with diameter of 1.5 to 5.0 cm allows exact adaptation to the size of the tumor bed, ensuring contact with all surfaces of the treatment area. The reusable spherical applicators offer convenience and accuracy. |
| |
 INTRABEAM Balloon Applicator | | INTRABEAM Balloon Applicator
In breast cancer treatment the Balloon Applicators add flexibility to the Spherical Applicators. Depending upon the surgical technique the skin incision can be kept smaller and irradiation can be administered peri-operatively outside the operating room.
Only FDA approved. CE mark pending. |
| |
 INTRABEAM Surgical Carrier System | | INTRABEAM Surgical Carrier System
Mobile and flexible. The carrier system combines performance with maximum reliability and flexibility. Electromagnetic couplings keep the radiation source in the set treatment position. The carrier makes INTRABEAM suitable for mobile use in any OR. |
| |
 INTRABEAM Surgical Carrier System | | INTRABEAM Cart
The cart ensures easy transportation inside and outside the operating room and it can be easily stowed away with all components when not in use. With the open space on top of the cart, the system quality check can be done easily on the cart serving as a workplace. The touch pad terminal, control console, dosimeter and everything else needed for system quality assurance and the treatment are mounted ergonomically on the cart. Large casters and guiding rollers ensure easy transportation inside and outside the operating room. The setup of the cart also ensures quick and easy cleaning in the OR. |
| |
 INTRABEAM Quality Assurance Tools | | INTRABEAM Quality Assurance Tools
A complete set of instrumentation for verifying dose output in a pre-treatment QA check is provided with the INTRABEAM.
A high precision Water Phantom enables independent verification of the dose rate energy and distribution for commissioning.
|
| |
| Ion Chamber: | Measures and displays radiation intensity |
| Probe Adjuster: | Measures probe straightness and adjusts to 0.1 mm runout. Holds IC |
| Photodiode Array: | Measures spatial radiation distribution |
| ERM External Radiation Monitor: | Detects radiation that exists the patient. ERM Test Adapter |
| Internal Radiation Monitor: | Counts X-rays emitted back along probe |
 Water Phantom | Enables independent verification of the dose rate energy and distribution |
| |
|